JHA for mini split installation
OSHA expects employers to find and control hazards on every job, and many general contractors require a written JHA for mini split installation before you start.
A JHA breaks the job into steps, lists the hazards in each step and the controls that protect the crew, and the crew signs it. The main hazards are falling from height, silica dust from concrete, brick, stone and tiles, electric shock from live wiring and fire from hot works.
JHA example: mini split installation
This is a complete JHA for mini split installation, with 10 job steps. Open it in the builder to add your site, crew and signatures, change anything, and download a PDF. Or download the free Word template below and fill it in by hand.
Job steps, hazards and controls
| # | Job step | Hazards | Risk before | Controls | Risk after |
|---|---|---|---|---|---|
| 1 | Plan unit positions, checking walls for cables and pipes |
| Critical |
| Medium |
| 2 | Set up a platform ladder or scaffold for high walls and the outdoor unit |
| Critical |
| Medium |
| 3 | Core drill the wall with dust extraction |
| Critical |
| Medium |
| 4 | Fix the wall bracket and mount the indoor unit |
| High |
| Medium |
| 5 | Lift the outdoor unit with two people onto its bracket or pad |
| Critical |
| Medium |
| 6 | Run and flare the pipework, brazing only under a hot work permit |
| Critical |
| Medium |
| 7 | Pressure test with dry nitrogen through a regulator, keeping clear of fittings under pressure |
| Medium |
| Low |
| 8 | Electrical connection by a licensed electrician, with the circuit isolated |
| Critical |
| Medium |
| 9 | Vacuum the system, open the service valves to let the outdoor unit's factory charge into the pipework, then commission |
| Medium |
| Low |
| 10 | Clean up and show the client how to use the system |
| Medium |
| Low |
PPE
Plant and equipment
Permits and plans
Emergency
Call 911. Add the nearest hospital, the assembly point and the first aid / cpr person for your site.
Sign-off
Supervisor and every worker sign to confirm they have read and understood this JHA.
Free JHA template for mini split installation
Word (.docx) and PDF, Letter landscape, no email needed. Fill in your site details, then print or send it.
Make yours in 2 minutes
Same document, filled in for your job. Answer a few yes or no questions, the crew signs on the phone, and you send the PDF.
Pre-start checklist for mini split installation
Tick these off before work starts. They come from the hazards, permits and equipment in this job.
- JHA read, explained and signed by everyone on the job
- Guardrails, nets or fall arrest in place before anyone works at 6 ft or more
- Ladder inspected, secured and extending 3 ft above the landing
- Lockout, tagout and test before touch done before work starts
- Water suppression or on-tool extraction fitted; respirators fit tested
- Hot work permit issued, extinguisher at hand, fire watch arranged
- First aid / CPR person, first aid kit and emergency number (911) confirmed
- PPE checked and worn: safety-toe boots (ASTM F2413), safety glasses (ANSI Z87.1), work gloves, N95 respirator
The safe sequence of work
- Plan unit positions, checking walls for cables and pipes
- Set up a platform ladder or scaffold for high walls and the outdoor unit
- Core drill the wall with dust extraction
- Fix the wall bracket and mount the indoor unit
- Lift the outdoor unit with two people onto its bracket or pad
- Run and flare the pipework, brazing only under a hot work permit
- Pressure test with dry nitrogen through a regulator, keeping clear of fittings under pressure
- Electrical connection by a licensed electrician, with the circuit isolated
- Vacuum the system, open the service valves to let the outdoor unit's factory charge into the pipework, then commission
- Clean up and show the client how to use the system
Hazards to watch on mini split installation
The hazards most specific to this job, and the step where each one comes up.
What changes on your site
This example covers the job itself. Your site may add more. Add controls for any of these that apply (the builder asks you these as yes or no questions):
- Will anyone work 6 feet or more above a lower level?
- Will anyone work on a roof?
- Is there a skylight, fiberglass panel or other fragile roofing?
- Will you use a scaffold or rolling tower?
- Will you use an aerial lift (scissor lift or boom lift)?
Why JHAs get rejected
General contractors send documents back for these reasons. This example avoids them, but check yours too.
- Generic steps such as "work safely" or "use PPE" with no task-specific hazards or controls.
- No OSHA standards referenced for the hazards that have them, such as fall protection, ladders, scaffolds or silica.
- No competent person named for fall protection, excavation, scaffolds or silica where those hazards exist.
- Equipment listed without inspection requirements, and no training listed for the people using it.
- Respirators listed with no respiratory protection program, medical clearance or fit test.
- Controls rely only on PPE when engineering controls such as guardrails, wet cutting or extraction are feasible.
- No crew sign-off, or no date and revision when the job has changed.
Questions
Do I need a JHA for mini split installation?
OSHA expects employers to find and control hazards on every job, and many general contractors require a written JHA for mini split installation before you start.
Who signs the JHA?
The supervisor or competent person who prepared it signs, and every crew member signs to show they were trained on the hazards and controls before the job starts. Many general contractors also sign to accept it.
How long do I keep it?
Keep this JHA on site during the job, and keep it with the training and inspection records for at least 1 year after the job (longer if your state plan or general contractor requires it). OSHA does not set a retention period for JHAs themselves.
What PPE is needed for mini split installation?
Usually Safety-toe boots (ASTM F2413), Safety glasses (ANSI Z87.1), Work gloves, N95 respirator, Hearing protection (earmuffs or plugs), Rubber insulating gloves, Arc flash PPE (NFPA 70E), Hard hat (ANSI Z89.1), Half-face respirator (P100 cartridges), Face shield (ANSI Z87.1), Welding gloves, Coveralls. The site rules may add more, so check with the general contractor.
More hvac JHAs